500VA output rating
Floating output complies with EN50191
Corona Discharge Detection (CDD, 19055-C)
Flashover Detection
Discharge Level Analysis (DLA)
Open Short Check (OSC)
High Frequency Contact Check (HFCC)
Ground Fault Interrupt
Standard RS-232 interface
Option GPIB & HANDLER interface
Key lock when fail
Programmable voltage & test limit
CE Mark
Support A190301 8HV Scanning Box
FUNCTIONS
Hi-Pot
- AC 5kV/100mA
- DC 6kV/20mAInsulation
- 5kVmax
- 1MΩ~50GΩAPPLICATIONS
Motor : The 19055 Series Hipot Analyzers with 500VA output rating can be used to test and analyze the withstand voltage of high power and leakage current for the products like motor stators and rotors with high parasitic capacitance. Corona detection can be used for turn-to-turn or turn-to-ground test to avoid winding insulation failure from corona discharge.Transformer : When using a power transformer under the normal voltage, a primary side corona discharge could cause the adjacent components to be damaged if occurred. Thus, the function of Corona Discharge Detection (CDD) of 19055-C can be used to detect if there is any corona discharge occurred to improve the product quality.
High Voltage Capacitor, Photocoupler & Insulation Material : If any gaps, voids or impurities appeared when doing molding in the manufacturing process, the insulation capability may be aected. The Corona Discharge Detection (CDD) equipped by 19055-C is able to defect if there is any corona discharge occurred to enhance the product quality. Chroma 19055 Ser ies Hipot Analyzer s are designed for hipot tests and analysis. The tests ofAC/DC/IR can be programmed in 5kV/100mA with 500VA output rating which complies with the EN50191requirements. (Please refer to the application notes for more detail information.)
The 19055-C has not only the AC/DC/IR tests but also a new measurement technology - Corona Discharge Detection (CDD) that can detect the following via the Discharge Level Analysis (DLA).
- Corona discharge Start Voltage (CSV)
- Flashover Start Voltage (FSV)
- BreakDown Voltage (BDV)As to the Contact Check during Hipot test, Chroma 19055 Series is equipped with a new function of High Frequency Contact Check (HFCC) besides the Open Short Check (OSC). By conducting the Contact Check during Hipot test, it can increase the test reliability and eciency signicantly.
For convenience use, Chroma 19055 has large LCD screen for operation and judgment. In addition, the GFi human protection circuit and Floating safety output prevent the operators from electrical hazard.