Features:

Minimum non-zero span sweep time: < 10 ms
Resolving power RBW: 10 Hz to 1 MHz
Sensitivity DANL: -130 dBm, -148 dBm with preamp on
Overall amplitude accuracy: ±0.5 dB
Customized power-on or “preset” enabled setups
Standard USB and LAN interface
Multiple language graphic user interface
Free remote control PC software

Measurement Capability:

Built-in power measurements: channel power, OBW, ACP, SEM and TOI
Built-in power meter function with Agilent U2000 series power sensor support
Optional tracking generator and preamplifier
Optional AM/FM, ASK/FSK demodulation capability

Agilent

N9320B RF Spectrum Analyzer

9 kHz to 3.0 GHz



Frequency and Time Specification

Frequency

Supplemental information


Range 9 kHz to 3 GHz AC coupled

100 kHz to 3 GHz Preamp on


Resolution 1 Hz

Internal 10 MHz frequency reference

Aging rate ± 1 ppm/year



Temperature stability ± 1 ppm 5 to +45 °C, reference 25 °C Supply voltage stability ± 0.3 ppm

Residual FM ≤ 100 Hz p-p in 100 ms nominal RBW = 1 kHz, VBW = 1 kHz

Frequency readout accuracy (start, stop, center, marker)

Marker resolution (freq span)/(number of sweep point -1)

Uncertainty ± (freq indication x freq reference uncertainty1 + 1% x span + 20% x resolution bandwidth + marker resolution)


Sweep point 461, fixed

Marker frequency counter

Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz Selectable


Accuracy ± [(marker freq x freq reference uncertainty1) + (counter resolution)]

Frequency span (FFT and swept mode)

Range 0 Hz (zero span), 100 Hz to 3.0 GHz


Resolution 1 Hz

Accuracy ± span/(swept points -1)

Sweep time and triggering


Span range 10 ms to 1000 s Span > 0 Hz


6 μs to 200 s Span = 0 Hz (minimum resolution = 6 μs) Mode Continuous, single

Trigger Free run, video, external

Trigger slope Positive or negative edge Selectable

Trigger delay 0 to 80 sweep time

Resolution bandwidth (RBW)


Range (-3 dB bandwidth) 10 Hz to 1 MHz, in 1-3-10 sequence

Accuracy ± 5% nominal

Resolution filter shape factor < 5:1 nominal

Range (-6 dB bandwidth) 200 Hz, 9 kHz, 120 kHz, 1 MHz EMI bandwidth (CISPR 16-1-1 complaint), requires Option EMF

Accuracy ± 10% nominal

Resolution filter shape factor < 5:1 nominal -60 dB/-6 dB bandwidth ratio

Video bandwidth (VBW)


Range 1 Hz to 1 MHz in 1-3-10 sequence -3 dB bandwidth

1. Frequency reference uncertainty = Aging rate x period since adjustment + supply voltage stability + temperature stability.

3

Amplitude Specifications

Amplitude range


Measurement range 10 MHz to 3 GHz: Displayed average noise level (DANL) to +30 dBm

(PA OFF) 1 to 10 MHz: DANL up to 23 dBm

100 kHz to 1 MHz: DANL up to 20 dBm

Input attenuator range 0 to 70 dB, in 1 dB steps

Maximum damage level

Supplemental information

Average continuous power ≤ +37 dBm Input attenuator setting ≥ 10 dB, 3 minutes maximum

Peak pulse power ≤ +50 dBm (100 W) For < 10 μs pulse width, < 1% duty cycle, and input attenuation ≥ 40 dB


DC voltage 50 VDC maximum

Level display range

Log scale units dBm, dBmV, dBμV, dBμA

Linear scale units μV, mV, V, μA, mA, A, μW, mW, W




Marker level readout 0.01 dB Log scale Resolution 0.01% of reference level Linear scale Number of traces 4
Detectors Positive-peak, negative-peak, sample, normal, RMS

Trace function Clear/write, maximum hold, average, minimum hold, view

Frequency response


10 dB input attenuation, reference: 50 MHz, 20 to -30 °C


200 kHz to 2.0 GHz ± 0.5 dB Preamp off

2.0 to 3.0 GHz ± 0.7 dB Preamp off

1 MHz to 2.0 GHz ± 0.6 dB Preamp on

2.0 to 3.0 GHz ± 0.8 dB Preamp on

Input attenuation switching uncertainty at 50 MHz

Attenuation > 2 dB, preamp off



0 to 60 dB attenuation ± 0.4 dB Relative to 10 dB (reference setting)

Absolute amplitude accuracy

Center frequency 50 MHz, RBW 1 kHz, VBW 1 kHz, amplitude scale log, span 100 kHz, sweep time coupled, peak detector, signal at reference level

Preamp off ± 0.3 dB Reference level -10 dB, input attenuation

10 dB
Preamp on ± 0.4 dB Reference level -30 dB, input attenuation

10 dB

4

Amplitude Specifications (continued)

Level measurement uncertainty

Supplemental information

20 to -30 °C; frequency > 1 MHz; signal input 0 to -50 dBm; reference level 0 to -50 dBm; input attenuation 20 dB; RBW

1 kHz, VBW 1 kHz; after calibration; preamp off


Overall amplitude accuracy ± 1.5 dB
± 0.5 dB, typical

Level display range



Log scale units dBm, dBmV, dBμV, dBμA


Linear scale and units W, mW, μW, A, mA, μA, V, mV, μV Marker level readout 0.01 dB


Resolution 0.01% of reference level Log scale Number of traces 4 Linear scale Detectors Positive-peak, negative-peak, sample,

normal, RMS
Trace functions Clear/write, maximum hold, average, minimum hold, view

Preamplifier



Frequency range 1 MHz to 3.0 GHz

Gain 18 dB nominal

5

Dynamic Range Specifications

1 dB gain compression

Supplemental information


Preamp off 50 MHz to 3.0 GHz > 0 dBm, typical; total power at input mixer

Preamp on 50 MHz to 3.0 GHz > -20 dBm, typical; total power at the preamp

Total power at the preamp = total power at the input

(dBm) - input attenuation (dB)

Displayed average noise level (DANL)


Input terminated, 0 dB RF attenuation, RBW = 10 Hz, VBW = 1 Hz, sample detector


Preamp off 9 to 100 kHz < -90 dBm, nominal

100 kHz to 1 MHz < -90 dBm – 3 x (f/100 kHz) dB

1 to 10 MHz < -124 dBm


10 MHz to 3 GHz < -130 dBm + 3 x (f/1 GHz) dB Preamp on 100 kHz to 1 MHz < -108 dBm – 3 x (f/100 kHz) dB

1 to 10 MHz < -142 dBm
10 MHz to 3 GHz < -148 dBm + 3 x (f/1 GHz) dB

Spurious response


Preamp off, signal input -30 dBm, 0 dB RF attenuation


Second harmonic distortion 10 to 200 MHz +30 dBm

200 to 500 MHz +35 dBm

500 MHz to 3 GHz +43 dBm

Preamp off, signal input -30 dBm, 0 dB RF attenuation


Third-order intermodulation (TOI) 300 MHz to 3 GHz +10 dBm; +13 dBm nominal

6

Dynamic Range Specifications (continued)

Spurious response (continued)

Supplemental information


Input related spurious < -60 dBc -30 dBm signal at input mixer, 20 to 30 °C


Residual response (inherent) < -83 dBc Input terminated and 0 dB RF attenuation, preamp off

Phase noise Specification Typical


Offset from CW signal 10 kHz < -88 dBc/Hz < -90 dBc/Hz

Fc = 1 GHz, RBW = 1 kHz, VBW = 10 Hz, and sample detector, log average, average times > 40
100 kHz < -100 dBc/Hz < -102 dBc/Hz

1 MHz < -110 dBc/Hz < -112 dBc/Hz
Residual FM ≤ 100 Hz peak-to-peak in 100 ms
1 kHz RBW, 1 kHz VBW

Tracking Generator Specifications (Option TG3 required)

Output frequency

Supplemental information


Range 100 kHz to 3 GHz Settable to 9 kHz


Resolution 1 Hz

Output power level

Range -30 to 0 dBm

Resolution 0.1 dB

Absolute accuracy ± 0.75 dB 20 to 30 °C, at 50 MHz with coupled source attenuator, referenced to -20 dBm

Output flatness ± 3 dB 100 kHz to 10 MHz

± 2 dB 10 MHz to 3 GHz



VSWR < 1.5:1 300 kHz to 3 GHz, input attenuator ≥ 12 dB Connector and impedance N-type female, 50 Ω

Maximum safe reverse level



Average total power 30 dBm (1 W) AC coupled 0 VDC MAX

7

Modulation Analysis Specifications

Demodulation

Frequency range 10 MHz to 3 GHz

Supplemental information






Carrier power accuracy ± 2 dB ± 1 dB typical Input power -30 to +20 dBm Auto attenuation Carrier power displayed resolution 0.01 dBm

AM measurement (included in Option AMA)


Modulation rate 20 Hz to 100 kHz

Accuracy 1 Hz, nominal Modulation rate < 1 kHz

< 0.1% modulation rate, nominal Modulation rate ≥ 1 kHz



Depth 5 to 95% Accuracy ± 4% nominal FM measurement (included in Option AMA) Modulation rate 20 Hz to 200 kHz

Accuracy 1 Hz, nominal Modulation rate < 1 kHz

< 0.1% modulation rate, nominal Modulation rate ≥ 1 kHz


Deviation 20 Hz to 400 kHz Accuracy ± 4% nominal ASK measurement (included in Option DMA)
Symbol rate range 200 Hz to 100 kHz

Modulation depth/index range 10 to 90%

Accuracy ± 4% of reading, nominal




Displayed resolution 0.1% FSK measurement (included in Option DMA) Symbol rate range 1 to 100 kH FSK deviation range 1 to 400 kHz

Accuracy ± 4% nominal β ≥1 and β≤4, β is the ratio of frequency deviation to symbol rate

Displayed resolution 0.01 Hz

8

Inputs and Outputs

Front panel

RF input connector N-type female, 50 Ω

Supplemental information





VSWR < 1.5:1 300 kHz to 3 GHz, input attenuator ≥ 10 dB Calibration output Amplitude -10 dBm ± 0.3 dB
Frequency 50 MHz

Accuracy Same as the frequency reference



Connector and impedance BNC-type female, 50 Ω Probe power Voltage/current +15 V, 150 mA maximum
-12.6 V, 150 mA maximum

RF output connector N-type female, 50 Ω Option TG3 installed


USB interface (host) A plug, version 1.1

Rear panel

10 MHz reference output Output amplitude > 0 dBm

Connector and impedance BNC-type female, 50 Ω

10 MHz reference input Input amplitude -5 to +10 dBm

Frequency lock range ± 5 ppm of specified external reference input frequency



Connector and impedance BNC-type female, 50 Ω External trigger input Input amplitude 5 V TTL level
Connector and impedance BNC-type female, 10 kΩ

VGA output VGA analog RGB 31.5 kHz horizontal, 60 Hz vertical sync rates, non-interlaced

D-sub 15-pin female connector VGA compatible




640 x 480 screen resolution LAN TCP/IP interface 10Base, RJ-45 connector USB interface (device) B plug, version 1.1
GPIB interface IEEE-488 bus connector Optional G01 installed

9

General

Temperature range



Operating +5 to +45 °C Storage -20 to +70 °C EMC
Complies with European EMC Directive 2004/108/EC
• IEC/EN 61326-1 or IEC/EN 61326-2-1
• CISPR Pub 11 group 1, class A
• AS/NZS CISPR 11:2004

• ICES/NMB-001:2004

This ISM device complies with Canadian ICES-001

Safety

Complies with European Low Voltage Directive 2006/95/EC
• IEC/EN 61010-1 2nd Edition
• Canada: CSA C22.2 No. 61010-1-04

• USA: UL 61010-1 2nd Edition

Audio noise


Acoustic noise emission




LpA < 70 dB Operator position Normal position Per ISO 7779

Environmental stress

Supplemental information

Samples of this product have been type tested in accordance with the Agilent Environmental Test Maunal and verified to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to, temperature, humidity, shock, vibration, altitude, and power line conditions. Test methods are aligned with IEC 60068-2

and levels are similar to MILPRF-28800F Class 3

Power requirements


Voltage and frequency (nominal) 100 to 240 VAC, 50 to 60 Hz Auto ranging

Power consumption < 65 W

Display


Resolution 640 x 480

Size 165.1 mm (6.5 in) diagonal (nominal)

Data storage


Internal 16 MB nominal

External Supports USB 2.0 compatible memory devices

10

General (continued)

Weight (without options)


Net 8.4 kg (18 lbs) nominal

Shipping 14.5 kg (32 lbs) nominal

Dimensions

Supplemental information

Height 132.5 mm (5.2 in) 3U rack height



Width 320 mm (12.6 in) Length 400 mm (15.7 in) Warranty

The N9320B spectrum analyzer is supplied with a one-year warranty

Calibration cycle

The recommended calibration cycle is one year. Calibration services are available through Agilent Service Centers

Descripton:

Regardless of whether your application is electronics’ manufacture, bench repair, RF education or R&D projects, you need a spectrum analyzer that is equipped with the essential functionality, required performance at an affordable price. The N9320B is designed to be the right answer for you.Enhanced Power Measurement and Easy Automated Test Programming Features

  • The accuracy of frequency selective power measurements when characterizing your products is very important. With a newly featured digital IF, the N9320B provides measurement accuracy and speed you need to accomplish tasks easily

  • Power meter functionality is a standard feature built-in with Agilent U2000 series power sensor support for highly accurate RF and MW power measurements

  • Direct access to perform one-button power measurement functions offer channel power, ACP, OBW, SEM and TOI measurements

  • For automated test programming, the N9320B provides industry standard SCPI language support and connectivity choices with USB and LAN. SCPI code compatible with Agilent ESA-L Series enables easy migration from ESA-L to the N9320B

Consolidated Solution for RF Teaching LabOne of the best ways to improve students’ learning efficiency for RF related curriculums is to combine lectures with hands-on labs. The N9320B is an excellent price-performance fit for educational purposes. Whether you wish to combine the N9320B analyzer with the Agilent N9310A RF signal generator for basic RF concept labs, or enhance your RF circuit labs with the N9320B and its optional RF training kit (option code: N9320B-TR1), you will find adopting Agilent’s RF education solution efficient and effective.


Item added to Inquiry Cart

Continue shopping Go to Inquiry Cart