Product Description
The HP Agilent 34401A Digital Multimeter gives you the performance you need for fast, accurate bench and system testing. The 34401A provides a combination of resolution, accuracy and speed that rivals DMMs costing many times more. 6½ digits of resolution, 0.0015% basic 24-hr dcV accuracy and 1,000 readings/s direct to GPIB assure you of results that are accurate, fast, and repeatable.
Features:
12 measurement functions
1000 V maximum input
15 ppm basic, dV accuracy (24 hour)
1000 readings per second direct to HP-IB
HP-IB and RS-232 standard
512-reading memory
SCPI commands standard
Specifications:
| Input Characteristics | |||
| Range | Maximum Reading (6½ digits) | Resolution in digits - 6½ | Input Resistance |
| 100 mV | 120.0000 | 100 nV | 10 M ohms or > 10 G ohms |
| 1V | 1.200000 | 1 µV | 10 M ohms or > 10 G ohms |
| 10 V | 12.00000 | 10 µV | 10 M ohms or > 10 G ohms |
| 100 V | 120.0000 | 100 µV | 10 M ohms |
| 1000 V | 1050.000 | 1 mV | 10 M ohms |
| Measurement Accuracy: ± (% or reading + % of range) | |||
| Range | 1-Year 23° C ±5° C | ||
| 100 mV | 0.0050 + 0.0035 | ||
| 1 V | 0.0040 + 0.0007 | ||
| 10 V | 0.0035 + 0.0005 | ||
| 100 V | 0.0045 + 0.0006 | ||
| 1000 V | 0.0045 + 0.0010 | ||
Agilent 34401A AC Voltage (true rms) Specifications:
| Frequency | Ranges 100 mV | Ranges 1, 10, 100 750 V | |
| 3 to 5 Hz | 1.00 + 0.04 | 1.00 + 0.03 | |
| 5 to 10 Hz | 0.35 + 0.04 | 0.35 + 0.03 | |
| 10 Hz to 20 kHz | 0.05 + 0.04 | 0.06 + 0.03 | |
| 20 to 50 kHz | 0.12 + 0.04 | 0.12 + 0.05 | |
| 50 to 100 kHz | 0.60 + 0.08 | 0.60 + 0.08 | |
| 100 to 300 kHz | 4.00 + 0.50 | 4.00 + 0.50 | |
| Measurement Accuracy | ± (%of reading + % of range); 1 year, 23° C ± 5° C | ||
Agilent 34401A Frequency and Period Specifications:
| Range | 3 Hz to 300 kHz (333 ms to 3.33 µs) |
| Resolution | 10 µHz to 1 Hz |
| Other Measurement Functions | Continuity, Diode Test, Ratio dc: dc, Limit Test |
| Math Functions | NULL, Min/Max/Avg, dB, dBm, Limit Test |
| Memory | 512 reading internal storage |
| Standard Programming Languages | SCPI, HP 3478A AND Fluke 8840A/42A |
| Computer Interface | HP-IB and RS-232C standard |
Agilent 34401A Resistance: (2-wire ohms, 4-wire ohms)
| Input Characteristics | ||
| Range | Maximum reading (6½) | Resolution in digits 6½ |
| 100 ohms | 120.0000 | 100 µ ohms |
| 1 k ohms | 1.200000 | 1 m ohms |
| 10 k ohms | 12.00000 | 10 m ohms |
| 100 k ohms | 120.0000 | 100 m ohms |
| 1 M ohms | 1.200000 | 1 ohms |
| 10 M ohms | 12.00000 | 10 ohms |
| 100 M ohms | 120.0000 | 100 ohms |
| Range | 1-Year 23° C ±5° C | ||
| 100 ohms | 0.010 + 0.004 | ||
| 1 k ohms | 0.010 + 0.001 | ||
| 10 k ohms | 0.010 + 0.001 | ||
| 100 k ohms | 0.010 + 0.001 | ||
| 1 M ohms | 0.010 + 0.001 | ||
| 10 M ohms | 0.040 + 0.001 | ||
| 100 M ohms | 0.800 + 0.010 | ||
| Measurement Accuracy | ± (% of reading + % of range) Specs are for 4-wire ohms or 2-wire ohms using Math Null | ||
Agilent 34401A DC Current Specifications:
| Range | 1-Year 23° C ±5° C |
| 10 mA | 0.050 + 0.020 |
| 100 mA | 0.050 + 0.005 |
| 1 A | 0.100 + 0.010 |
| 3 A | 0.120 + 0.020 |
| Input Protection | Externally accessible 3A 250V fuse; internal 7A 500V fuse |
Agilent 34401A AC Current (True Rms) Specifications:
| Frequency | Ranges 1A | Ranges 3A | |
| 3 to 5 Hz | 1.00 + 0.04 | 1.10 + 0.06 | |
| 5 to 10 Hz | 0.30 + 0.04 | 0.35 + 0.06 | |
| 10 Hz to 5 kHz | 0.10 + 0.04 | 0.15 + 0.06 | |
| Measurement Accuracy | ± (% of reading + % of range); 1 year, 23° C ± 5° C | ||