Fluke 99B ScopeMeter

The new ScopeMeter IIB with ultra bright high contrast display uses sophisticated technology to provide 25 MSPS acquisition rate and 100MHz bandwidth.  The Series IIB features random repetitive sampling rates of 5 Gigasamples/sec. Your ScopeMeter test tool combines the capabilities of an easy-to-use digital storage oscilloscope with the versatility of a digital multimeter. When you select a measurement function, the test tool automatically chooses the best setup to analyze and compare complex waveforms, or simply to read voltage levels.


ScopeMeter test tool features include:

  • Digital Storage Oscilloscope.

  • 3 2/3-digit, 5-MHz Digital MultiMeter (DMM).

  • Battery power.

  • Measure menu for quick setup.

  • Continuous Auto Set? function for hands-off signal probing.

  • Large memory for front panel Setups, Waveforms, and Screens.

  • Min Max TrendPlot? function with time stamp for long term recording.

  • Optical to RS-232 interface port, 600V isolation.

  • Instant Information key.



Specifications:


Scope Mode
VerticalBandwidth
100 MHz (Fluke 105B and Fluke 99B)
Coupling
AC, DC, Ground
Sensitivity
1 mV to 100 V/div (With included 10:1 probe measure up to 600 Vrms)
Modes
A, -A, B, -B, A+B, A-B, X vs. Y
Vertical resolution
8 bits (256 levels)
Accuracy
【(2% of reading +1 pixel)
HorizontalRange
5 ns/div to 60 s/div (Fluke 105B and Fluke 99B)
Acquisition modes
Recurrent, Single shot, Envelope, Roll, Glitch detect, Average, ScopeRecord™
Maximum sample rate
5 GS/s (Fluke 105B and Fluke 99B),  for repetitive
signals; 25 MS/s for single shot, all models
Maximum record length
Scope Record™(Fluke 105B, 99B & 96B only)
30k (up to 20ms/div-1 ch)
15k (up to 20ms/div-2 ch)
512 samples per channel (up to 5ns/div) (all models)
Accuracy
【(-0.1% of reading +1 pixel)
TriggerSource
Input A, Input B, External
Modes
Free run, Triggered, Single
Types
Edge, Video, Event, N-cycle
Video
Triggers on Field 1, Field 2, Lines or selectable line number
Interlaced video
NTSC, PAL, PAL/M, SECAM, User selectable 2-Field or 4-Field sequence
Non Interlaced video
Line selection up to 3200 lines
Line frequency
14 kHz to 65 kHz
Time delay
Up to 20 divisions pre trigger view
Up to 640 divisions trigger delay
Cursor Measurements(Fluke 105B, 99B and 96B only)
Up to 5 displayed simultaneously, Vrms (AC), Frequency, Vmean (DC), Risetime,
Vpeak-peak, Time between cursors, Vmax-peak, Time at cursors (Time of day or Time
from start), Vmin-peak, Phase dV between cursors, V at cursors. Measurements can be
scaled to Amperes. Readouts in % change or delta-zero.
Waveform Mathematics(Fluke 105B and 99B only)
Add, multiply, filter, subtract, invert, integrate. Instantaneous or mean watts with
optional current probes.
ZoomAdjustable magnification. Allows full 30k record overview, or zoom in to single sample
resolution.
Memory Save and Recall(Fluke 105B, 99B and 96B only)
Setup Memories
40 for Fluke 105B and 99B,
Waveform Memories
20 for Fluke 105B and 99B,
Screen Memories
10 for Fluke 105B and 99B,
Meter ModeDC Voltage
Ranges
100 mV to 300V
(With included 10:1 probe measure up to 600 Vrms)
Accuracy
【(0.5%+5 counts)
AC or AC+DC true rms Voltage
Ranges
100 mV to 250V
(with included 10:1 probe measure up to 600 Vrms)
Accuracy
50 Hz to 60 Hz 【(1%+10 counts)
20 Hz to 20 kHz 【(2%+15 counts)
5 Hz to 1 MHz 【(3%+20 counts)
DC to 5 MHz 【(10%+25 counts)
Additional MeasurementsContinuity, Diode test, Amps, Hz, ∑C or ∑F, Pulse Width, Duty Cycle, RPM, dBm,
dBV, dBW, Audio or RF Watts. (Amps, ∑C or ∑F with Optional Probes)
Advanced METER FunctionsTouch Hold, Change Alert™, Smoothing™, Continuity Beeper. Readouts in % change, %
scale or delta-zero.
MIN MAX Trend PlotChart recording function to log MIN, MAX, and AVERAGE readings. Displays all 3
readings as graphs with time and date stamp. Automatic vertical scaling and horizontal
time compression for recording from 120 seconds to 40 days.
Signal Generator(Fluke 105B and Fluke 99B only)
Sinewave
1V pk-pk at 976 Hz with <-3% distortion
Squarewave
5V pk-pk at 488 Hz, 976 Hz, or 1.95 kHz
Component Tester
Current or voltage ramp with 128 steps
General SpecificationsThe accuracy of all measurements are within 【(1% of ready 【 number of counts)
from 18∑C to 28∑C. Add 0.1 x (specified accuracy) for each ∑C<18∑C or >28∑C.
DisplayCold cathode fluorescent back-lit liquid crystal
Size
84x84 mm (3.3x3.3 inch)
Contrast and brightness
User adjustable
Real-time clockStamps Min Max TrendPlots and 30k records with time and date.
PowerLine voltage adapter/battery charger included
Installed battery Rechargeable NiCad Pack
Operating time 4 hours typical
Charging time 21 hours typical
Alternate battery 4 Alkaline C cells
(user supplied) (non rechargable)Environmental
Temperature -- O∑C to 50∑C
Shock and Vibration MIL-T-28800D for class 3
Drip and dust proof IP51 according to IEC529