upgradeable microwave power amplifier solution with field proven reliability. Developed to cover the frequency band 1.0 - 4.0 GHz in two bands (1 GHz to 2 GHz and 2 GHz to 4 GHz), the topology has significant advantages over single band solutions. This Amplifier is a standard 3U high units, (with bench case options), and may be combined in rack mounted form to build higher power amplifiers.
Features and Specifications of the Milmega AS0104-55/55 Dual Band Broadband Amplifier include:
Class leading linearity and noise specifications:
Gain variation with temperature <0.06 dB/°C
IP3 typically 10 dB> P1 dB
Harmonics –20 dBc min
Spurious (max) –70dBc
Spurious (typical) –80 dBc
Max power:
Unbeatable power density
Series 2000 will maintain full forward power into any load condition
Combiner/coupler integration as standard allows samples of incident and reflected power to be measured with virtually no loss
100% tested into short and open circuit
Up to 250 watts in a single 3U unit
Consistent over greater than octave bandwidths
Broadband CW power output to 1 kW
RF Input: Type N female
RF Output: Type N female
Power 1.0 - 2.0 GHz:
Psat (min): 56.0 W
Psat (min) 47.5 dBm
P1dB (min): 50.0 W
P1dB (min): 47.0 dBm
Noise figure (max): 6.0 dB
Power 2.0 - 4.0 GHz:
Psat (min): 56.0 W
Psat (min) 47.5 dBm
P1dB (min): 50.0 W
P1dB (min): 47.0 dBm
Noise figure (max): 8.0 dB
High visibility status and power indicators:
Series 2000 incorporate color led bar graph displays on the front panel giving an indication of incident and reflected power
Other standard features:
15 way rear mounted D-type allowing remote operation via TTL commands whilst providing access to an output signal sample
All data is measured at 25 °C driven from a 50 R source and driving into a 50 R load
Input power (for rated output) 5 dBm
Input power (no damage) 15 dBm
Input VSWR (impedance 50 R nominal) 2:1 max
Output VSWR (impedance 50 R nominal) 2:1 typical
Load VSWR (any phase) is infinite
Line input frequency 47-65 Hz
Operating temperature (ambient air) 0 to 40 °C
Storage temperature -40 to 70 °C
Built-in protection:
In the event of internal temperature exceeding 70 °C, the amplifier blocks will automatically switch off to avoid damage
Unit incorporates a rear panel mounted connector for interlock BR2-female