I.membrane filters description UF is a separation technique similar to that of Reverse Osmosis (R0). The main differences between the two are that: RO separates virtually all dissolved molecules (ions), while OF retains molecules above a certain size and allow some smaller molecules (ions) to pass through as product, OF are rated according to the molecular weight (MWCO) of the solutes removed;
II. membrane filters technical data
Raw Material
PP
External Shape
Hollow fiber
Diameter Inside
320um-350um
Diameter Outside
400um-450um
Pore Size
0.02um-0.2um
Pore Density
40%-50%
X-axis Strength
120Mpa
Ventilation Rate
>7.0x102cm3/cm2.s.cmHg
Available Temp.
4-45
PH
0-14
Molecule cut
50000-80000
Ref. pressure
0.1-0.3Mpa
III. membrane filters tech data of the feed in water
The size of particle
≤50um
BOD5
≤30mg/L
Turbidity
≤20NTU
CODcr
≤50mg/L
PH
1-14
Temp.
4-40
Working pressure
≤0.25Mpa
Max. pressure
≤0.40Mpa
Inlet Temperature: 15~40 °C
Outlet SDI: ≤3
Inlet pressure ≤0.25 MPa
Trans-membrane pressure difference ≤0.08 MPa
Recovery rate ≥ 90%
IV.membrane filters Cleaning
The chemical cleaning depends upon the pollutants type of inlet water. Only backwash cannot wholly remove the scolds, which causes the degradation of UF performance over time. In order to recover the previous filter performance, chemical cleaning is necessary. The leaner can be acid, sodium hydroxide, sodium hypochlorite, disinfectants.
Similar Products
Condition : NEW
Model#: Millipore part # WCDSF04L1
Location:
Model#: Millipore Cytofluor
Location:
Manasquan, New Jersey, USA
Condition : USED
Model#: Millipore Gen 2 Terminal
Location:
Condition : USED
Model#: Millipore Gen II Controller
Location:
Condition : USED
Model#: Millipore Gen II plus Contol
Location: