- Test & Measurement
-
Analyzers
-
Oscilloscope
-
Meters
-
Generators
-
DC Power Supply
-
Optical Communications
-
Other Test Equipment
-
Accessories
-
Probes
-
Software
-
AC Power Sources
-
Accessory Kits
-
Amplifiers
-
Antenna
- View All Categories >>
-
- Semiconductor & PCB
-
Front End
-
Back End
-
PC Board Assembly
- View All Categories >>
-
- Surplus & Liquidation
- Computers & Electronics
- Construction
-
Aggregate Equipment
-
Air Compressors
-
Asphalt / Pavers / Concrete Equipment
-
Compactors
-
Cranes
-
Crawler Loaders
-
Dozers
-
Drills
-
Dumpers
-
Excavators
-
Forestry Equipment
-
Forklifts
-
Generator Sets
-
Lifts
- View All Categories >>
-
- Biotech & Life Sciences
-
Biotechnology
-
Cell Counters
-
DNA Sequencers
-
DNA Synthesizers
-
Densitometers
-
Electrophoresis
-
Electroporation
-
Fermenters / Bioreactors
-
Flow Cytometers
-
Gel Dryer
-
Hybridization Ovens/Incubators
-
Immunoassay Systems
-
Microarray Scanners
-
Microplate Dispensers
- View All Categories >>
-
- Machinery
-
Abrasives
-
Air Compressors
-
Air Cooling & Heating Equipment
-
Bar Machinery
-
Bending & Forming Equipment
-
Boring Mills
-
Broaching Machines & Keyseaters
-
CNC Machinery
-
Chemical & Processing Equipment
-
Chip, Recycling & Scrap Equipment
-
Cleaning, Painting & Washing Equipment
-
Coil Processing Equipment
-
Construction Equipment
-
Die Casting Machines
- View All Categories >>
-
- Commercial Trucks
-
Heavy Duty Trucks
-
Medium Duty Trucks
-
Light Duty Trucks
-
Trailers
- View All Categories >>
-
- Chemical Equipment
-
AGITATORS
-
AIR FIN COOLERS
-
BLENDERS
-
BLOW MOLDERS
-
BLOWERS
-
BOILERS
-
CENTRIFUGES
-
COLUMNS
-
COLUMNS DBL DIA
-
COMPLETE PLANTS
-
COMPRESSORS
-
CONVERTERS
-
CONVEYORS
-
COOLING TOWERS
- View All Categories >>
-
- Apparel and Textile
-
Textile Machinery
-
Apparel & Textile Machinery Parts
-
Apparel Machinery
-
Home Textile Product Machinery
-
Apparel Accessories Machinery
-
Leather Production Machinery
- View All Categories >>
-
- Medical Equipment
-
Beds, Stretchers and Furniture
-
Cardiology
-
Consumables and Supplies
-
Cosmetic
-
Defibrillator
-
Dental
-
EMS/Rescue
-
Endoscopy
-
Exam Room
-
Homecare/Rehab
-
Imaging
-
Laboratory
-
Monitors/ICU/CCU
-
Neonatal
- View All Categories >>
-
- Printing Equipment
-
Press
-
Prepress
-
Postpress
-
Guillotines
-
Packaging
-
Misc
-
Flexo Printing
-
Web offset
-
Screen Printing
-
Package deals
-
Spare Parts
- View All Categories >>
-
- Packaging Equipment
-
Accumulators
-
Bag Dumps
-
Bag Sealers
-
Bagging Machines
-
Blister Packaging Lines
-
Blister Packers
-
Blister Sealers
-
Blow Fill Seal
-
Bottle Rinsers
-
Canning Equipment
-
Cap Sorters
-
Cappers
-
Cartoners
-
Case Erectors
- View All Categories >>
-
Novel Power Amplifier For A MEMS-Based Energy Harvest
05/05/2013 21:59:13
Imec and Holst Centre have used a secondary mass-spring system to increase the power of a MEMS-based energy harvester.
They demonstrated power amplification up to a factor of 51 by simply placing a packaged harvester on top of a thin metal beam. This solution can easily be implemented in real applications, for which the power (or bandwidth) generated by the original MEMS harvester is insufficient.
Vibration energy harvesters rely on the amplification of an input vibration by putting a seismic mass at mechanical resonance. The mechanical energy of the resonating mass is then partly converted into electrical energy, e.g. by a variable capacitor (electrostatic harvester) or by a piezoelectric capacitor (piezoelectric harvester). The power output typically ranges from 50 up to 500µW.
Imec and Holst Centre have developed a method of amplifying the power output of such a harvester by placing the packaged MEMS harvester on a steel beam. This is analogous to adding a second mass and spring to the original harvester mass-spring system. Imec says this method is very useful for applications for which the vibrations are too small to generate useful power. It is also suitable for applications with sinusoidal vibration sources such as engines, for which the bandwidth of the harvester is too small.
By adding a second mass-spring system, a coupled oscillator is created in which the second mass consists of the mass of the package of the harvester and the mass of the additional beam. The presence of this system splits the original resonance frequency of the harvester into two frequencies.
The photograph at the top shows the experimental setup. The packaged MEMS harvester is placed on top of a thick metal beam. The beam is clamped and attached to a shaker.
By tuning the ratios of the masses (ratio = α) and spring constants (ratio = β) of both systems (harvester and beam/package), the two amplitudes can become larger than the original amplitude of the harvester. For a steel beam of only a few centimetres long, this happens when the mass of the harvester (typically 0.039g) is 100 times smaller than the sum of the masses of beam and package. By using this method, power amplification up to a factor of 51, leading to a sensitivity of 1.2mW/g2has been demonstrated for a piezoelectric harvester.
![]()
The power output for a piezoelectric harvester with fh of 1011Hz (external input= 0.08g). An amplification factor of 51.3 times is obtained (α = β = 212)
The researchers also investigated the feasibility of implementing the additional mass-spring system in real applications where other electronics are needed. A possible embodiment is to place a steel beam on top of a PCB, on which the ICs as well as the rechargeable battery are placed. They found that the maximum vibration amplitude of the metal beam is around 50µm, requiring only minimal extra volume. It will thus be easy to integrate the proposed setup in, for example, an existing wireless sensor node.

